RDOL Motor Starter Supply and Control with Thermistor Protection – Performance Level e (PL e) example

This example shows the power supply and control of a reversing direct-on-line (RDOL) motor starter, including an additional thermistor protection relay for monitoring the motor temperature. The circuit allows the motor to operate in both clockwise and counterclockwise directions.

The three-phase supply is taken from the busbar -L1, -L2 and -L3 and connected to the motor circuit breaker -Q10. The motor circuit breaker provides protection for the motor circuit against short circuits and overloads.

The protected three-phase supply is then connected to the reversing contactor assembly -Q12. This assembly contains two contactors that change the phase sequence supplied to the motor, allowing its direction of rotation to be reversed. The contactors are interlocked to prevent both directions from being activated simultaneously.

The reversing contactor assembly -Q12 is controlled by two safety outputs:

  • Q320.1 – Motor start clockwise.

  • Q320.2 – Motor start counterclockwise.

A separate main contactor -Q11 is installed in the motor power circuit and controlled by safety output Q320.3. This provides an additional switching element for the safety-related motor shutdown function.

The motor circuit also includes a Siemens thermistor motor protection relay -KT2. The relay monitors the motor temperature through the thermistor connections T1 and T2, connected to the motor thermistor through terminal group -XG2. If the motor temperature exceeds the permitted limit, the relay changes its output contact state and provides a signal to the control system.

The thermistor relay feedback is connected to PLC input I303.0, allowing the PLC to monitor the motor thermal protection status.

The motor circuit breaker -Q10 provides an auxiliary feedback signal to PLC input I303.1, allowing the control system to monitor the status of the motor protection device.

The contactors also provide feedback signals to the PLC:

  • I303.2 – Clockwise contactor feedback.

  • I303.3 – Counterclockwise contactor feedback.

  • I303.4 – Main contactor -Q11 feedback.

These signals allow the control system to monitor the actual switching states and detect discrepancies between the commanded and actual states of the motor starter.